Shanghai GOM Testing & Technical Co,Ltd.

产品展示

Lamps and lanterns CE Certification
发表时间:2018-07-02     阅读次数:624

Lamps and Lanterns CE

SummaryLamps and Lanterns CE testCE certification requirements

CE -Common Lamps and Lanterns

Lamps and Lanternsa device that, by definition, allocates, transmits, or transmits light from one or more light sourcesand wrap the parts necessary to support, fix, and protect the light sourceBut do not contain the light source itself),and the necessary circuit AIDS and facilities to connect them to the power supplyIn the current market, Lamps and Lanterns have a wide range of productscan be divided by light sourceincandescent lampfluorescent lampLED lamp etc. Can be divided according to installation waymoveable Lamps and Lanternsdesk lampHanging wall lampfloor lamp etc. Stationary type Lamps and Lanternsceiling lampwall lampembedded lampTrack lamp etc.

EU regulation or Directive for Lamps and Lanterns CE

LVD 2014/35/EU

EMC 2014/30/EU

Lamps and Lanterns CE standard

LVD 2014/35/EU

EN 60598-1: Luminaires — Part 1: General requirements and tests

EN 60598-2-1 Luminaires — Part 2: Particular requirements — Section 1: Fixed general purpose luminaires

EN 60598-2-2 Luminaires — Part 2-2: Particular requirements — Recessed luminaires

EN 60598-2-3 Luminaires — Part 2-3: Particular requirements — Luminaires for road and street lighting

EN 60598-2-4 Luminaires — Part 2: Particular requirements — Section 4: Portable general purpose luminaires

EN 60598-2-5 Luminaires — Part 2-5: Particular requirements — Floodlights

EN 60598-2-7 Luminaires — Part 2: Particular requirements — Section 7: Portable luminaires for garden use

EN 60598-2-8 Luminaires — Part 2-8: Particular requirements — Handlamps

EN 60598-2-9 Luminaires — Part 2: Particular requirements — Section 9: Photo and film luminaires (non-professional)

EN 60598-2-10 Luminaires — Part 2-10: Particular requirements — Portable luminaires for children

EN 60598-2-11 Luminaires — Part 2-11: Particular requirements — Aquarium luminaires

EN 60598-2-12 Luminaires — Part 2-12: Particular requirements — Mains socket-outlet mounted nightlights

EN 60598-2-13 Luminaires — Part 2-13: Particular requirements — Ground recessed luminaires

EN 60598-2-14 Luminaires — Part 2-14: Particular requirements — Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment

EN 60598-2-17 Luminaires — Part 2: Particular requirements — Section 17: Luminaires for stage lighting, television film and photographic studios (outdoor and indoor)

EN 60598-2-19 Luminaires — Part 2: Particular requirements — Section 19: Air-handling luminaires (safety requirements)

EN 60598-2-20 Luminaires — Part 2-20: Particular requirements — Lighting chains

EN 60598-2-21 Luminaires — Part 2-21: Particular requirements — Rope lights

EN 60598-2-22 Luminaires — Part 2-22: Particular requirements — Luminaires for emergency lighting

EN 60598-2-23 Luminaires — Part 2-23: Particular requirements — Extra low-voltage lighting systems for filament lamps

EN 60598-2-24 Luminaires — Part 2-24: Particular requirements — Luminaires with limited surface temperatures

EN 60598-2-25 Luminaires — Part 2-25: Particular requirements — Luminaires for use in clinical areas of hospitals and health care buildings

。。。。。。

EMC 2014/30/EU

EN 55015: Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

EN 61547: Equipment for general lighting purposes - EMC immunity requirements

EN 61000-3-2: Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)

EN 61000-3-3: Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

Lamps and Lanterns CE test

LVD 2014/35/EU

l Durability test of CE label

l Screw fastening test

l Hanging test

l Cable fixation experiment

l Earth test

l IP

l Insulation resistance and dielectric strength

l Leakage Current

l Creepage distance and electrical clearance

l Durability test

l Thermal test

l Prevent fire and electrical stain

l Mechanical property test

。。。。。。

EMC 2014/30/EU

EMIREradiationemission),CE(Conducted Emission),HarmonicFlicker

EMSESDEFTDIPCRSSurgePMS

Lamps and Lanterns CE

1. Submit specification manual, drawing etc. to confirm the CE standard

2. Send sample test according to applicable CE standard requirement

3. Submit a full set of CE technical files

4. Notified body review all the reports and documents

5. Issue CE certificate

6. Labeled with CE mark, enter EU market

CE Label-Lamps and Lanterns

1) CE mark is two semicircles, which can be scaled up or down according to the size of the package

2) The minimum size of CE mark shall not be less than 5mm

3) If the instruction does not specify a specific size, the two letters CE mark must have the same vertical height and must not be less than 5mm

4) The CE mark must be clearly and not easily obliterated

>>Shanghai GOM Testing & Technical Co., Ltd.as an authoritative third-party testing and certification agencyhave experienced engineers provide professional technical support, and qualified laboratories provide you with the latest international standard testing >>

Contact us: 021-34122669, 18018853504, info@cegaomeng.com


返回首页