Cables CE Summary:Cables CE test,CE certification requirements CE -Common types of wire and cable: Usage:Power Cable,Communication Cable,Control Cable etc. Material:PVC cable,Rubber cable,Halogen-free cables etc. Structure:bare wire,Single core unsheathed cable,Multicore sheathed cable,armoured cable,shielded cable etc. Cables CE standard LVD Directive 2014/35/EU EN 50525-1:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 1: General requirements EN 50525-2-11:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) — Part 2-11: Cables for general applications — Flexible cables with thermoplastic PVC insulation EN 50525-2-12:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) — Part 2-12: Cables for general applications — Cables with thermoplastic PVC insulation for extensible leads EN 50525-2-21:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) — Part 2-21: Cables for general applications — Flexible cables with crosslinked elastomeric insulation EN 50525-2-22:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-22: Cables for general applications — High flexibility braided cables with crosslinked elastomeric insulation EN 50525-2-31:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-31: Cables for general applications — Single core non-sheathed cables with thermoplastic PVC insulation EN 50525-2-41:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-41: Cables for general applications — Single core cables with crosslinked silicone rubber insulation EN 50525-2-42:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-42: Cables for general applications — Single core non-sheathed cables with crosslinked EVA insulation EN 50525-2-51:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-51: Cables for general applications — Oil resistant control cables with thermoplastic PVC insulation EN 50525-2-71:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-71: Cables for general applications — Flat tinsel cables (cords) with thermoplastic PVC insulation EN 50525-2-72:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-72: Cables for general applications — Flat divisible cables (cords) with thermoplastic PVC insulation EN 50525-2-81:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-81: Cables for general applications — Cables with crosslinked elastomeric covering for arc welding EN 50525-2-82:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-82: Cables for general applications — Cables with crosslinked elastomeric insulation for decorative chains EN 50525-2-83:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 2-83: Cables for general applications — Multicore cables with crosslinked silicone rubber insulation EN 50525-3-11:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 3-11: Cables with special fire performance — Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke EN 50525-3-21:2011/AC:2013 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 3-21: Cables with special fire performance — Flexible cables with halogen-free crosslinked insulation, and low emission of smoke EN 50525-3-31:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 3-31: Cables with special fire performance — Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke EN 50525-3-41:2011 Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) — Part 3-41: Cables with special fire performance — Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke EN 50618:2014 Electric cables for photovoltaic systems 。。。。。。 CPR Regulation (EU) No 305/2011 EN 50575:2014/A1:2016 Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements Remark:2017.7.1,all power, communication and control cables exported to European Union buildings shall not only comply with the LVD directive and ROHS directive, but also meet the requirements of the European Union's CPR (EU) code of No.305/2011. CE test -Cables LVD 2014/35/EU l Dimension Measurement l Conductor Resistance l Insulation Resistance l Withstand Voltage Test l Aging Test l CE marking 。。。。。。 CPR Regulation (EU) No 305/2011 1)Reaction to fire:EN ISO 1716, EN 50399, EN 60332-1-2, EN 61034-2, EN 60754-2 2)Dangerous substances release Certification process-cables CE 1. Submit specification manual, drawing etc. to confirm the CE standard 2. Send sample test according to applicable CE standard requirement 3. Submit a full set of CE technical files 4. Notified body review all the reports and documents 5. Issue CE certificate 6. Labeled with CE mark, enter EU market CE mark-Cables 1) The CE mark should be clearly visible and not easily erased 2) It can be marked on the insulation layer or sheath layer 3) There should be CE mark,manufacturer, voltage, size, the related standard etc. info. >>Shanghai GOM Testing & Technical Co., Ltd.,as an authoritative third-party testing and certification agency,have experienced engineers provide professional technical support, and qualified laboratories provide you with the latest international standard testing >> 
Contact us: 021-34122669, 18018853504, info@cegaomeng.com
|