Shanghai GOM Testing & Technical Co,Ltd.

产品展示

Transformer CE Certification
发表时间:2018-09-06     阅读次数:760

Transformer CE

SummaryTransformer CE TestCE Certification Requirements

CE Certification- Common transformer products

Classified by cooling methodDry type (self-cooling) transformer, oil immersed (self-cooling) transformer, fluoride (evaporation cooling) transformer;

Classified by Moistureproof wayOpen type transformer, filling type transformer, seal type transformer;

Classified by core or coil structureCore type transformer (chip core, C type core, ferrite core), shell type transformer (chip core, C type core, ferrite core), ring type transformer, metal foil transformer;

Classified by power phase numberSingle-phase transformer, three-phase transformer, multiphase transformer;

Classified by usagePower transformer, frequency transformer, pulse transformer.

EU Regulation/Directive for Transformer CE

LVD 2014/35/EU

EMC 2014/30/EU

Transformer CE Standard

EN 61050:1992 Transformers for tubular discharge lamps having a no-load output voltage exceeding 1 kV (generally called neon-transformers) — General and safety requirements

EN 61558-1:2005 Safety of power transformers, power supplies, reactors and similar products — Part 1: General requirements and tests

EN 61558-2-1:2007 Safety of power transformers, power supplies, reactors and similar products — Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications

EN 61558-2-1:2007 Safety of power transformers, power supplies, reactors and similar products — Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications

EN 61558-2-3:2010 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-3: Particular requirements and tests for ignition transformers for gas and oil burners

EN 61558-2-4:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V — Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers

EN 61558-2-5:2010 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformer for shavers, power supply units for shavers and shaver supply units

EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V — Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers

EN 61558-2-7:2007 Safety of power transformers, power supplies, reactors and similar products — Part 2-7: Particular requirements and tests for transformers and power supplies for toys

EN 61558-2-8:2010 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-8: Particular requirements and tests for transformers and power supply units for bells and chimes

EN 61558-2-9:2011 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-9: Particular requirements and tests for transformers and power supply units for class III handlamps for tungsten filament lamps

EN 61558-2-12:2011 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-12: Particular requirements and tests for constant voltage transformers and power supply units for constant voltage

EN 61558-2-13:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V — Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers

EN 61558-2-14:2013 Safety of transformers, reactors, power supply units and combination thereof — Part 2-14: Particular requirements and tests for variable transformers and power supply units incorporating variable transformers

EN 61558-2-15:2012 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-15: Particular requirements and tests for isolating transformers for the supply of medical locations

EN 61558-2-16:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V — Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units

EN 61558-2-16:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V — Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units

EN 61558-2-23:2010 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-23: Particular requirements and tests for transformers and power supply units for construction sites

EN 61558-2-26:2013 Safety of transformers, reactors, power supply units and combinations thereof — Part 2-26: Particular requirements and tests for transformers and power supply units for saving energy and other purposes

Transformer CE Test Item

Marking and other information

Protection against electric shock

Change of input voltage setting

Output voltage and output current under load

No-load output voltage

Short-circuit voltage

Heating

Short circuit and overload protection

Mechanical strength

Protection against harmful ingress of dust, solid objects and moisture

Insulation resistance, dielectric strength and leakage current

Construction

Components

Internal wiring

Supply connection and other external flexible cables or cords

Terminals for external conductors

Provisions for protective earthing

Screws and connections

Creepage distances, clearances and distances through insulation

Resistance to heat, fire and tracking

Resistance to rusting

Transformer CE Process

1. Submit specification manual, drawing etc. to confirm the CE standard

2. Send sample test according to applicable CE standard requirement

3. Submit a full set of CE technical files

4. Notified body review all the reports and documents

5. Issue CE certificate

6. Labeled with CE mark, enter EU market

CE Label- Transformer

1) CE mark is two semicircles, which can be scaled up or down according to the size of the package

2) The minimum size of CE mark shall not be less than 5mm

3) If the instruction does not specify a specific size, the two letters CE mark must have the same vertical height and must not be less than 5mm

4) The CE mark must be clearly and not easily obliterated

>>Shanghai GOM Testing & Technical Co., Ltd.as an authoritative third-party testing and certification agencyhave experienced engineers provide professional technical support, and qualified laboratories provide you with the latest international standard testing >>

Contact us: 021-34122669, 18018853504, info@cegaomeng.com


返回首页
客服电话
短信咨询
回到顶部