Glass Test
Summary:Tempered glass, laminated glass, coated glass European standard test introduction
1. Tempered glass European standard test
l Test standard:
EN 12150-1: 2015 Glass in building – thermally toughened soda lime silicate safety glass
l Test item:
| Test item | Test standard |
6 | Dimensions and tolerances | |
6.1 | Nominal thickness and thickness tolerances | EN 12150-1 |
6.2 | Width and length (sizes) | EN 12150-1 |
6.3 | Flatness | EN 12150-1 |
7 | Edge work, holes, notches and cut-outs | EN 12150-1 |
8 | Fragmentation test | EN 12150-1 |
9 | Other physical characteristics | |
9.1 | Other physical characteristics | EN 12150-1 |
9.2 | Anisotropy (iridescence) | EN 12150-1 |
9.3 | Thermal durability | EN 12600 |
9.4 | Mechanical strength | EN 1288-3 |
9.5 | Classification of performance under accidental human impact | EN 12600 |
Remark:Tempered glass CE certification standard is EN 12150-2:2004 Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard
2. Laminated glass European standard test
l Test standard:
EN 14449: 2005 Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard
l Test item
Test item | Test standard | |
4.2, 4.3.1 and 4.3.2.1 | Resistance to fire | EN 13501-2 |
4.2, 4.3.1 and 4.3.2.2 | Reaction to fire | EN 13501-1 |
4.2, 4.3.1 and 4.3.2.3 | External fire performance (for roof coverings only) | prEN 13501-5 |
4.2, 4.3.1 and 4.3.2.4 | Bullet resistance: Shatter properties and resistance to attack | EN 1063 |
4.2, 4.3.1 and 4.3.2.5 | Explosion resistance: Impact behaviour and resistance to attack | EN 13541 |
4.2, 4.3.1 and 4.3.2.6 | Burglar resistance: Shatter properties and resistance to attack | EN 356 |
4.2, 4.3.1 and 4.3.2.7 | Pendulum body impact resistance: Shatter properties(safe breakability) and resistance to impact | EN 12600 |
4.2, 4.3.1 and 4.3.2.8 | Mechanical resistance: Resistance against sudden temperature changes and temperature differentials | EN 1096-4 |
4.2, 4.3.1 and 4.3.2.9 | Mechanical resistance: Resistance against wind, snow, permanent and imposed load and/or imposed loads of the glass unit | EN 13474 |
4.2, 4.3.1 and 4.3.2.10 | Protection against noise:-Direct airborne sound reduction | EN 12758 |
4.2, 4.3.1 and 4.3.2.11 | Thermal properties | EN 673 |
4.2, 4.3.1 and 4.3.2.12 4.2, 4.3.1 and 4.3.2.13 | Radiation properties: - light transmittance and reflectance - solar energy characteristics
| EN 410 |
3. Coated glass European standard test
l Test standard
EN 1096-4: 2004 Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard
l Test item
Test item | Test standard | |
4.2, 4.3.1 and 4.3.2.1 | Resistance to fire (for glass for use in a glazed assembly intended specifically for fire resistance) | EN 13501-2 |
4.2, 4.3.1 and 4.3.2.2 | Reaction to fire | EN 13501-1 |
4.2, 4.3.1 and 4.3.2.3 | External fire performance (for roof coverings only) | prEN 13501-5 |
4.2, 4.3.1 and 4.3.2.4 | Bullet resistance: Shatter properties and resistance to attack | EN 1063 |
4.2, 4.3.1 and 4.3.2.5 | Explosion resistance: Impact behaviour and resistance to attack | EN 13541 |
4.2, 4.3.1 and 4.3.2.6 | Burglar resistance: Shatter properties and resistance to attack | EN 356 |
4.2, 4.3.1 and 4.3.2.7 | Pendulum body impact resistance: Shatter properties(safe breakability) and resistance to impact | EN 12600 |
4.2, 4.3.1 and 4.3.2.8 | Mechanical resistance: Resistance against sudden temperature changes and temperature differentials | EN 1096-4 |
4.2, 4.3.1 and 4.3.2.9 | Mechanical resistance: Resistance against wind, snow, permanent and imposed load and/or imposed loads of the glass unit | EN 13474 |
4.2, 4.3.1 and 4.3.2.10 | Protection against noise:-Direct airborne sound reduction | EN 12758 |
4.2, 4.3.1 and 4.3.2.11 | Thermal properties | EN 673 |
4.2, 4.3.1 and 4.3.2.12 4.2, 4.3.1 and 4.3.2.13 | Radiation properties: - light transmittance and reflectance - solar energy characteristics
| EN 410 |
Shanghai GOM provide professional European standard test & certification service for glass, contact us: 021-34122669