    Glass Test

    SummaryTempered glass, laminated glass, coated glass European standard test introduction

    1. Tempered glass European standard test

    l Test standard

    EN 12150-1: 2015 Glass in building – thermally toughened soda lime silicate safety glass

    l Test item:

    Test item

    Test standard

    6

    Dimensions and tolerances


    6.1

    Nominal thickness and thickness tolerances

    EN 12150-1

    6.2

    Width and length (sizes)

    EN 12150-1

    6.3

    Flatness

    EN 12150-1

    7

    Edge work, holes, notches and cut-outs

    EN 12150-1

    8

    Fragmentation test

    EN 12150-1

    9

    Other physical characteristics


    9.1

    Other physical characteristics

    EN 12150-1

    9.2

    Anisotropy (iridescence)

    EN 12150-1

    9.3

    Thermal durability

    EN 12600

    9.4

    Mechanical strength

    EN 1288-3

    9.5

    Classification of performance under accidental human impact

    EN 12600

    RemarkTempered glass CE certification standard is EN 12150-2:2004 Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard

    2. Laminated glass European standard test

    l Test standard

    EN 14449: 2005 Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard

    l Test item


    Test item

    Test standard

    4.2, 4.3.1 and 4.3.2.1

    Resistance to fire

    EN 13501-2

    4.2, 4.3.1 and 4.3.2.2

    Reaction to fire

    EN 13501-1

    4.2, 4.3.1 and 4.3.2.3

    External fire performance (for roof

    coverings only)

    prEN 13501-5

    4.2, 4.3.1 and 4.3.2.4

    Bullet resistance: Shatter properties

    and resistance to attack

    EN 1063

    4.2, 4.3.1 and 4.3.2.5

    Explosion resistance: Impact behaviour and resistance to attack

    EN 13541

    4.2, 4.3.1 and 4.3.2.6

    Burglar resistance: Shatter properties and resistance to attack

    EN 356

    4.2, 4.3.1 and 4.3.2.7

    Pendulum body impact resistance:

    Shatter properties(safe breakability)

    and resistance to impact

    EN 12600

    4.2, 4.3.1 and 4.3.2.8

    Mechanical resistance: Resistance

    against sudden temperature

    changes and temperature

    differentials

    EN 1096-4

    4.2, 4.3.1 and 4.3.2.9

    Mechanical resistance: Resistance

    against wind, snow, permanent and

    imposed load and/or imposed loads

    of the glass unit

    EN 13474

    4.2, 4.3.1 and 4.3.2.10

    Protection against noise:-Direct

    airborne sound reduction

    EN 12758

    4.2, 4.3.1 and 4.3.2.11

    Thermal properties

    EN 673

    4.2, 4.3.1 and 4.3.2.12

    4.2, 4.3.1 and 4.3.2.13

    Radiation properties:

    - light transmittance and reflectance

    - solar energy characteristics

    EN 410

    3. Coated glass European standard test

    l Test standard

    EN 1096-4: 2004 Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard

    l Test item


    Test item

    Test standard

    4.2, 4.3.1 and 4.3.2.1

    Resistance to fire (for glass for use in a glazed assembly intended specifically for fire resistance)

    EN 13501-2

    4.2, 4.3.1 and 4.3.2.2

    Reaction to fire

    EN 13501-1

    4.2, 4.3.1 and 4.3.2.3

    External fire performance (for roof

    coverings only)

    prEN 13501-5

    4.2, 4.3.1 and 4.3.2.4

    Bullet resistance: Shatter properties

    and resistance to attack

    EN 1063

    4.2, 4.3.1 and 4.3.2.5

    Explosion resistance: Impact behaviour and resistance to attack

    EN 13541

    4.2, 4.3.1 and 4.3.2.6

    Burglar resistance: Shatter properties and resistance to attack

    EN 356

    4.2, 4.3.1 and 4.3.2.7

    Pendulum body impact resistance:

    Shatter properties(safe breakability)

    and resistance to impact

    EN 12600

    4.2, 4.3.1 and 4.3.2.8

    Mechanical resistance: Resistance

    against sudden temperature

    changes and temperature

    differentials

    EN 1096-4

    4.2, 4.3.1 and 4.3.2.9

    Mechanical resistance: Resistance

    against wind, snow, permanent and

    imposed load and/or imposed loads

    of the glass unit

    EN 13474

    4.2, 4.3.1 and 4.3.2.10

    Protection against noise:-Direct

    airborne sound reduction

    EN 12758

    4.2, 4.3.1 and 4.3.2.11

    Thermal properties

    EN 673

    4.2, 4.3.1 and 4.3.2.12

    4.2, 4.3.1 and 4.3.2.13

    Radiation properties:

    - light transmittance and reflectance

    - solar energy characteristics

    EN 410

    Shanghai GOM provide professional European standard test & certification service for glass, contact us: 021-34122669