欢迎来到Shanghai GOM Testing & Technical Co,Ltd.官网! 中文版|English加入收藏|设为首页
专业认证,用心服务信誉第一、服务领先!
服务热线:021-34122669

Contact us

  • Contact:Dream Liu
  • Phone:021-34122669
  • Mobile:18018853504
  • QQ:1312447001
  • Address:NO. 609 Tahui Road,Shihudang Town,Songjiang District,Shanghai
  • 产品认证位置:首页 > 产品认证
    Steel structure, Aluminum structure - EN1090 CE Certification
    Product Categories :铁塔,输电线塔架,钢结构房屋,钢结构别墅,温室结构,光伏支架等
    CE certification cost:请咨询认证工程师
    Issue Date:2018-06-28
    Views:
    Tel:021-34122669
    Keywords:钢结构CE认证,铝结构CE认证,建材CE认证,建材CPR认证,钢结构EN1090认证

    详细介绍

    Steel structure, aluminum structure EN1090 CE certification

    Common steel structure, aluminum structure products

    Steel TowerTransmission wire pylonsSteel Housessteel work villagreenhouse structurePhotovoltaic stents

    CE regulation for steel structure & aluminum structure

    Construction products (CPR) Regulation (EU) No 305/2011

    CE standard for steel structure & aluminum structure

    l EN 1090-1:2009+A1:2011 Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components

    l EN 1090-22008 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures

    l EN 1090-32008 Execution of steel structures and aluminium structures - Part 3: Technical requirements for aluminum structures

    CE test item for steel structure & aluminum structure

    l Tolerances on dimensions and shape

    l Weldability

    l Fracture toughness, Impact resistance

    l Load bearing capacity

    l Fatigue strength

    l Resistance to fire

    l Reaction to fire

    l Release of cadmium and its compounds

    l Emission of radioactivity

    l Durability

    System of VOCP for steel structure & aluminum structure

    System 2+notified body initial FPC inspection

    Tasks for the certification body

    l Tasks under the responsibility of the manufacturerInitial type testing; Factory Production Control (FPC); Sampling, testing and inspection at the factory

    l Tasks for the certification bodyInitial inspection of factory and of FPC; Continuous surveillance, assessment and approval of FPC

    Execution class of steel structure & aluminum structure

    Four execution classes 1 to 4, denoted EXC1 TO EXC4, are given, for which requirement strictness increases from EXC1 to EXC 4

    Execution classes may apply to the whole structure or to a part of the structure or to specific details. A structure can include several execution classes. A detail or group of details will normally be ascribed one execution class. However, the choice of an execution class does not necessarily have to be the same for all requirements.

    If no execution class is specified EXC 2 shall apply.

    Welding

    Welding shall be undertaken in accordance with the requirements of the relevant part of EN ISO 3834 or EN ISO 14554 as applicable.

    Qualification of welding procedureWPQR-EN1090

    Welding shall be carried out with qualified procedures using a welding procedure specification (WPS) in accordance with the relevant part of EN ISO 15609 or EN ISO 14555 or EN ISO 15620, as relevant.

    Welders and welding operators -EN1090

    Welders shall be qualified in accordance with EN ISO 9606(replace EN 287-1), and welding operators in accordance with EN ISO 14732(replace EN 1418).

    Welding coordination -EN1090

    For EXC2, EXC3, EXC4, welding coordination shall be maintained during the execution of welding by welding coordination personal suitably qualified for, and experienced in the welding operations they supervise as specified in EN ISO 14731.

    FPC工厂生产控制-钢结构、铝结构CE认证要求

    that products placed on the market conform to the declared performance characteristics.

    The FPC system shall consist of written procedures, regular inspections and tests and/or assessments and the use of results to control the component’s constituent products, equipment, the production process and the manufactured component.

    A FPC system conforming to the requirements of EN ISO 9001 and made specific to the requirements of this European standard shall be considered to satisfy the above requirements.

    NOTE A quality system does not necessarily need to be in accordance with EN ISO 9001 to satisfy the requirements to FPC of this European Standard.

    The results of inspections, tests and assessments stated in the manufacturer`s FPC system shall be recorded.

    The action to be taken if control values or criteria are not met shall be recorded and retained for the period specified in the manufacturer’s FPC procedures.

    FPC

    l Personnel

    l Equipment

    l Structural design process

    l Constituent products used in manufacture

    l Component specification

    l Product evaluation

    l Non-conforming products


    Shanghai GOM have many domestic factories EN1090 steel structure, aluminum structure CE certification experiencethe certification engineer can provide you with the most professional construction CE certification services in the most rapid time

    Tel: 021-34122669 18018853504